Cross-border flight
Flight plan + radioNormally file at least 60 minutes before departure and establish ATS contact at entry
VFR Guide Europe
At a glance
Normally file at least 60 minutes before departure and establish ATS contact at entry
Use GEN 3.4 and current SIA VFR charts
5,000 ft is only the reference where no other value is published
With operative A/C and altitude reporting unless ATS instructs otherwise
Check French ULM definition; otherwise obtain a DSAC laissez-passer
Schengen, PPF, customs and local airfield conditions.
Read more →Border flight, lead time, activation and closure.
Read more →Compulsory radio communication in the case of a motor-driven VFR approach.
Read more →French sector-dependent flight information services.
Read more →Classes A, C, D, E and G and special areas.
Read more →VMC-Minima, Special VFR and FL195.
Read more →cruising levels, TA and national crossing levels.
Read more →requirements for SEPs; ULM basically Tag-VFR.
Read more →Squawk 7000, TMZ/RMZ and 8,33 kHz.
Read more →French ULM definition and DSAC laissez-passer.
Read more →VAC/TXT, PPR, French only and ULM restrictions.
Read more →Military low-flight corridors and activations.
Read more →Local overflight restrictions and sensitive areas.
Read more →European minimum cover according to MTOM.
Read more →ULM right, 600-kg -UL, SIA cards and SOFIA.
Read more →The flight operational statements are based on the official sources researched for this France edition.
AIP basis: AIRAC 08/26 - valid 06.08.2026 to 02.09.2026. State of the research: 23.08.2026
France is part of the EU and the Schengen area. For entry by air, a distinction must be made between personal border control, customs and the aviation regulations for border crossing.
For a direct flight, for example from Germany, Belgium, Luxembourg, Spain or Italy, there is no obligation to fly to a PPF simply because of the person crossing the border. The local conditions of the destination airport - in particular PPR, operating hours and permitted types of traffic - remain relevant. Regardless of this, the flight plan requirement applies to international VFR flights.
For a direct flight to or from a state or territory outside the Schengen area, the French AIP generally requires an airport with status PPF - Point de Passage Frontalier. The flight must take place within the published opening hours of the responsible border control post.
Schengen and customs territory are two different situations. For flights from countries or areas outside the EU customs territory, additional customs formalities may be required. Special goods and special areas remain to be checked separately.
Before a flight from a non-EU customs area: also check the Douane / Police section of the destination airport as well as AIP GEN 1.3 and the current VAC/TXT page.
A flight plan is required for any flight that crosses an international border. France generally requires such flights to be checked in no later than 60 minutes before departure. If a flight plan is exceptionally submitted in the air, it must reach the responsible ATS at least ten minutes before the planned entry into the relevant controlled area or before the relevant route point. The border crossing point must be entered in field 15; the estimated time to cross the border is given in field 18 under EET/.
If a prescribed flight plan is required for a purely domestic French VFR flight, the regular minimum lead time is 30 minutes. In addition, there are special French flight plan requirements for certain areas, routes and VFR flights over sea. For overwater flights, ENR 1.1 must therefore be checked before concrete planning.
The French SIA provides SOFIA briefing for electronic flight preparation. Flight plans, NOTAM and other briefing information can be edited there. VFR flight plans can generally be submitted up to a maximum of 24 hours before EOBT.
If taking off from an airfield without ATS, the actual departure must be communicated to ATS in accordance with French flight planning procedures. A VFR flight plan required for an international flight must remain in effect throughout the entire international flight. After landing, make sure that the flight plan has actually been closed. The AIP also provides for closure by telephone via the responsible BRIA.
According to VFR, a motor-powered aircraft may only fly into French metropolitan airspace if it is equipped with radio communications equipment. When crossing the border, a two-way radio connection must be established with the relevant French ATS office; In practice, the responsible FIS/SIV is a good option.
This means that the assumption that an international engine-powered VFR flight to France can be carried out completely without radio in exclusively uncontrolled airspace is not correct.
France has the FIR Paris, Reims, Brest, Bordeaux and Marseille for Metropolitan France. There are also numerous SIV - Secteurs d'Information de Vol, which play an important role, particularly for VFR traffic. The callsigns are, for example, PARIS Information, MARSEILLE Information or LYON Information. The relevant frequencies depend on the sector and are published in AIP GEN 3.4 and on the current VFR maps.
Do not adopt a rigid nationwide frequency list from older guides. The French SIA has released several map corrections in 2026. Therefore, take over the FIS/SIV frequencies from the current SIA map or AIP immediately before the flight.
France uses airspace relevant to VFR, particularly classes C, D, E and G; There is also Class A airspace, particularly in the Paris area. The metropolitan FIRs generally range from SFC to FL195. Outside designated controlled areas, there is predominantly airspace G.
France generally applies SERA; national additions and published deviations are included in the AIP.
Area flight visibility cloud distance
from / above 10,000 ft AMSL 8 km 1,500 m horizontal / 1,000 ft vertical
below 10,000 ft and above the 5 km 1,500 m horizontal / 1,000 ft vertical higher value from 3,000 ft AMSL and 1,000 ft AGL respectively
In lower airspace G, the SERA relief applies: basically outside of clouds and with ground visibility; The flight visibility permitted there depends on the SERA conditions and, if applicable, nationally approved reductions.
Special VFR may be possible within a CTR with ATC clearance. There are significant restrictions on Special VFR at night in France; a normal SEP cruise flight should not be planned with a nighttime SVFR clearance.
Normal VFR traffic above FL195 is not intended according to SERA. Exceptions are only in expressly set up reserved airspace or with special procedures up to a maximum of FL285 possible and do not represent a normal VFR travel option.
For horizontal cruise flight above 3,000 ft above ground or water, the VFR semicircle flight areas according to magnetic heading apply.
Magnetic heading VFR flight surfaces
000°-179° FL35, 55, 75, 95, 115, 135, 155, 175...
180°-359° FL45, 65, 85, 105, 125, 145, 165, 185...
Transition altitude is not a uniform fixed value everywhere in France. The Transition Altitude is published for the respective TMA. The AIP uses 5,000 ft as a reference value unless another value is published; different transition altitudes are indicated on the corresponding maps. The transition level is determined depending on the air pressure.
In addition to the general SERA minimum altitudes, France has distinctive national regulations for flying over built-up areas and certain installations.
Area/Situation Guideline for single-engine piston aircraft
isolated establishments, certain industrial facilities, at least 300 m from French hospitals, recreational centers and designated regulation facilities
Smaller towns with a width of less than 1,200 m regularly 500 m / approx. 1,700 ft
Larger settlement areas / large gatherings of people up to 1,000 m / 3,300 ft or 1,500 m / 5,000 ft, depending on the category
Paris: Overflying is generally not permitted, except under specially approved exceptions. The relevant areas and settlement widths must be checked using the current French VFR maps.
Night VFR is generally permitted in France, but only under published conditions. A flight plan is required for a night VFR flight that goes beyond the immediate vicinity of an airfield. The departure and destination airports must be suitable for the planned night operations and must be published accordingly. Increased minimum altitudes apply outside special published night VFR routes. Over high or mountainous terrain, at least 2,000 ft above the highest obstacle within 8 km must be maintained, otherwise at least 1,000 ft above the highest obstacle within 8 km; National French additions must also be taken into account.
For ULM according to the French definition, the following applies since July 1, 2025: VFR by day. Normal night VFR operations with a French rule-compliant ULM are therefore not planned.
For a VFR flight with a functioning Mode A+C transponder and Alticoder, the following generally applies in France without any other ATS instruction:
Squawk 7000 altitude transmission switched on.
This rule generally applies during the flight; Traffic patterns are excluded. If only Mode A is available without altitude transmission, the transponder should generally not be switched on independently with VFR as long as ATS does not assign a code.
In a published TMZ or RMZ-TMZ, an SSR transponder with Mode A/C or Mode S is required, unless the respective publication provides otherwise. In RMZ or RMZ-TMZ, the required initial radio call must be made before entry and then remain ready to listen.
Where VHF radio is required, the equipment must comply with the European 8,33-kHz requirements. Since radio is required for a motor-driven VFR border entry to France, an incoming SEP or UL should be practically equipped with 8,33-kHz-capable radio.
Communication with French ATS offices may generally take place in French or English. If an aviation chart expressly states “French only / français uniquement”, only French is intended.
Especially at smaller airports, check before planning your flight whether the location is published as “French only”.
The French UL rules differ significantly from the 600-kg regulations in force in Germany.
European UL that meets the French ULM definition A UL registered or approved in an EEA state, Switzerland or the United Kingdom that also meets the French definition of a ULM may in principle be operated for non-commercial flights in France without prior airworthiness-related approval from the DSAC.
For the French Class 3 - Multiaxe, MTOM 500 kg generally applies to two-seaters. With a rescue parachute, 25 kg can be added. Additional surcharges apply for seaplanes.
Consequence: A typical German or other European 600-kg multiaxis UL with piston engine is not automatically recognized as a French ULM in France only because it can be legally operated with 600 kg in its home state.
If the aircraft does not meet the French ULM definition, the DGAC treats it as “ultraléger européen non ULM”. Then a laissez-passer from the DSAC is required beforehand. The DSAC can authorize a stay of a maximum of 90 cumulative days within the last twelve months for such European ultralight aircraft. Additional documentation and operating conditions apply.
The French category ULM-S must not be confused with a normal 600-kg piston engine UL. It concerns special series-produced aircraft with turbine propulsion and their own mass limits.
For a European ULM that corresponds to the French ULM definition, the pilot title issued or recognized by the registration state is generally accepted. In the case of a European ultralight aircraft that does not meet the French ULM definition, a decision from the French DSAC may also be necessary for the pilot.
For French ULM rated aircraft, VFR applies during the day.
In addition to controlled airfields, France has a very large number of smaller airfields and ULM platforms. Before each flight, the current VAC and TXT page of the respective seat must be checked.
This point is exceptionally important for France.
The RTBA - Réseau Très Basse Altitude is a network of military low-altitude flight corridors or restricted areas. Fighter aircraft can fly low there at very high speeds. When activated, flying through the relevant RTBA zone is not permitted; the zone must be flown around. The actual or planned activation will be published via SIA -> Preparation de vol -> Activités Défense -> AZBA and via NOTAM. AZBA does not replace NOTAM, AIP and SUP AIP.
France publishes numerous local overflight restrictions and recommended minimum altitudes for sensitive areas. These should not be adopted as a rigid national table. Current ICAO cards, AIP ENR 5, VAC, SUP AIP and NOTAM are particularly relevant. This particularly applies to natural parks, military areas, nuclear facilities, metropolitan areas and temporary security zones.
The European minimum insurance rules of Regulation (EC) No. 785/2004 generally apply to aircraft operators.
MTOM minimum third party liability coverage
under 500 kg 0.75 million SDR
under 1,000 kg 1.5 million SDR
under 2,700 kg 3 million SDR
under 6,000 kg 7 million SDR
The regulation generally applies to aircraft flying into, out of, or over the territory of an EU member state. There are special regulations regarding individual risks for certain light aircraft; this is not a general exemption from aviation liability.
The following current test points must be checked based on the relevant official publications.
AIP / eAIP France, VAC, SUP AIP, NOTAM, SOFIA briefing and AZBA. • SIA - current eAIP / product numériques
This country overview supports flight preparation, but does not replace checking current AIP/eAIP, VAC, SUP AIP, NOTAM, AZBA/RTBA, weather information and any required regulatory approvals immediately before the flight.
Especially with foreign 600-kg -UL: Before entering, it must be clarified whether the specific aircraft complies with the French ULM definition or whether a DSAC laissez-passer is required.
Official direct links
The AIP, supplements, NOTAM, weather and aerodrome data valid on the day of flight remain authoritative. Links open the respective official source in a new window.
This country guide supports individual flight preparation. It does not replace the AIP, AIP SUP, NOTAM, AUP/UUP, weather and aerodrome information valid on the day of flight.
Systematic reproduction, compilation or redistribution of the complete VFR Guide Europe is prohibited.